Maison>Produits>Tapered Roller Bearings>Bearing 580/572 KBC
Bearing 580/572 KBC 580/572 KBC MODELS
Need a CAD or 3D Model?
Bearing 580/572 KBC
Tapered Roller Bearings
Bearing 580/572 KBC 580/572 KBC Bearing SPECIFICATIONS
- Bearing 580/572 KBC
580/572 KBC
- Crystal2020-07-10 09:46:19
Welcome to my shop! Glad to serve you! Please send your question!
Bearing 580/572 KBC 580/572 KBC Description du produit
Tapered roller bearings 580/572
Bearing number : 580/572
Size mm : 82.55x139.992x36.512
Brand : KBC
Bore Diameter mm : 82.55
Outer Diameter mm : 139.992
Width mm : 36.512
Bearing dimensions and specification in brand catalogue :
d - 82.55 mm
D - 139.992 mm
T - 36.512 mm
B - 36.098 mm
C - 28.575 mm
a - 31.2 mm
r1 min. - 3.5 mm
r2 min. - 3.5 mm
r3 min. - 3.3 mm
r4 min. - 3.3 mm
Weight - 2.178 Kg
Basic dynamic load rating C - 175 kN
Basic static load rating C0 - 260 kN
Grease Lubrication Speed - 2600 r/min
Oil Lubrication Speed - 3400 r/min
Calculation factor e - 0.4
Calculation factor Y - 1.5
Calculation factor Y0 - 0.82
Catalogue,Brandslist,,Bearing 580/572 KBC
Bearing 580/572 KBC Shielded bearings have a storage life of five years and a further two years operational life following installation. Wash all bearing parts with a noncontaminating solvent. Lightly pack the bearings with grease applying a 33% fill by volume into the bearing and housings. Where Bearing 580/572 KBC space heaters are fitted, and the storage environment has wide humi dity and temperature variations, it is strongly recommended they be energised. Warnings should be placed on the Bearing 580/572 KBC to make operatives aware of the live heaters Supplies are normally 220-240 volt single phase, from a 380-415 volt three phase supply. See terminal box lid for details.
Bearing 580/572 KBC Shielded bearings have a storage life of five years and a further two years operational life following installation. Wash all bearing parts with a noncontaminating solvent. Lightly pack the bearings with grease applying a 33% fill by volume into the bearing and housings. Where Bearing 580/572 KBC space heaters are fitted, and the storage environment has wide humi dity and temperature variations, it is strongly recommended they be energised. Warnings should be placed on the Bearing 580/572 KBC to make operatives aware of the live heaters Supplies are normally 220-240 volt single phase, from a 380-415 volt three phase supply. See terminal box lid for details.
Insulation resistance During extended storage a three monthly insulation test is recommended to avoid possible lengthy drying out periods when installing Bearing 580/572 KBC. Use a 500 volt d.c. Megger.The insulation resistance between phases and between the windings and the frame should be checked. The insulation resistance should be maintained above 10 megohm. If a lower reading is measured, use one of the drying out methods recommended on page 14 until an acceptable reading is obtained. If heaters are fitted but not energised, they should be used in future. Wound rotors Ideally, wound Bearing 580/572 KBC brushes should not be in contact with the slip-rings during storage as there is a risk of corrosion. Brushes should either be lifted off the slip-rings or stored separately. This may not be possible with small Bearing 580/572 KBC.
Insulation resistance During extended storage a three monthly insulation test is recommended to avoid possible lengthy drying out periods when installing Bearing 580/572 KBC. Use a 500 volt d.c. Megger.The insulation resistance between phases and between the windings and the frame should be checked. The insulation resistance should be maintained above 10 megohm. If a lower reading is measured, use one of the drying out methods recommended on page 14 until an acceptable reading is obtained. If heaters are fitted but not energised, they should be used in future. Wound rotors Ideally, wound Bearing 580/572 KBC brushes should not be in contact with the slip-rings during storage as there is a risk of corrosion. Brushes should either be lifted off the slip-rings or stored separately. This may not be possible with small Bearing 580/572 KBC.
Insulation resistance During extended storage a three monthly insulation test is recommended to avoid possible lengthy drying out periods when installing Bearing 580/572 KBC. Use a 500 volt d.c. Megger.The insulation resistance between phases and between the windings and the frame should be checked. The insulation resistance should be maintained above 10 megohm. If a lower reading is measured, use one of the drying out methods recommended on page 14 until an acceptable reading is obtained. If heaters are fitted but not energised, they should be used in future. Wound rotors Ideally, wound Bearing 580/572 KBC brushes should not be in contact with the slip-rings during storage as there is a risk of corrosion. Brushes should either be lifted off the slip-rings or stored separately. This may not be possible with small Bearing 580/572 KBC.
Bearing 580/572 KBC 580/572 KBC INTERCHANGE
Tapered Roller Bearings Part series 580/572 KBC is a potential replacement for these common bearing part numbers:
580/572 KBC
580/572 KBC
580/572 KBC
580/572 KBC
580/572 KBC
580/572 KBC
580/572 KBC
580/572 KBC
Contactez-nous
- Adresse
- téléphone professionnel(Temps de travail)
- Fax
Bearing 580/572 KBC 580/572 KBC Technical Articles
La gestion et l'entretien de la pompe à engrenages à haute température |
Commune de failles et de solutions de pompe à boue |
La cause technique de l’apurement de diamètre de bague et arbre pompe à vis |
Tapered Roller Bearings CATEGORIES
- Tapered Roller Bearings
- parker PV piston pump
- CONTROLLER
- FURNAN PUMP
- Plain Bearing
- Cylindrical Roller Bearings
- PRECISION BALL BEARINGS
- Vickers vane pump
- Bearing catalog
- VICKERS Piston pump
- PRECISION BALL BEARINGS
- Tapered Roller Bearings
- Needle Roller Bearing
- CRUSHER
- POWER TRAIN ASS
- YUKEN vane pump
- TRACK FRAME
- Cylindrical Roller Bearing
- bearing online
- Self-Aligning Ball Bearings
- NACHI piston pump
- REVOLVING FRAME
Customers Who Viewed Bearing 580/572 KBC 580/572 KBC Bearing Also Viewed
- Mots clés:
KBC
82.55x139.992x36.512